This is the Allen Bradley Micrologix 1400 Analog Trainer with everything you need to start your PLC programming career. Designed for both schools and individuals who wish to learn more than the basic trainers and instruction manuals can teach.
You can find all of your curriculum in the Lessons section including the "Allen Bradley RsLogix 500 PLC Trainer Lessons" and the "Designing And Building Electrical Control Panel Lessons".
The Micrologix 1400 PLC includes 10 discrete 24VDC inputs, 6 discrete 24VDC outputs, 2 analog inputs, and 2 analog outputs. RsLogix 500 Micro Starter is included with your trainer.
The trainer requires 120VAC and plugs into your typical wall outlet. The drive outputs 230 VAC to the three phase fan drive which is pre-wired on the trainer.
In addition to learning PLC programming and troubleshooting, these lessons will teach you how to wire and diagnose control systems. This curriculum will help you gain valuable insight into how industrial control panels are wired and operate. All circuits in these self paced lessons are 24VDC.
Your trainer includes:
- Push Button - Your trainer comes with four push buttons. A green, yellow, and blue momentary push button and a red maintained mushroom button (note image does not show mushroom button). Each button has two normally open (NO) contacts and two normally closed (NC) contacts. The normally open contacts are color coded green and the normally closed contacts are color coded red on the back of the trainer.
- Selector Switch 2 Position - Your trainer has two 2 position selector switches. There is a normally open contact on each selector switch that closes when you turn the switch to the right (clockwise).
- Selector Switch 3 Position - Your trainer has two 3 position selector switches. There is a normally open contact for both the left and right position of the selector switch.
- Lights - Your trainer has four lights colored green, yellow, red, and blue.
- Analog Potentiometer and Gauge - Your trainer has a 10K potentiometer and a 4-20mA analog gauge.
- Contactor Relay - Your trainer has one contactor/relay which is an open style so you can see how it works. It is a double pole double throw which means it has two sets of contacts with both normally open and normally closed positions.
- AC Drive - Your trainer has a AC inverter drive which takes 120VAC in and creates 240VAC 3 phase out so this trainer can be used to learn about 3 phase power yet plugs into a standard wall outlet.
- 24VDC Power Supply - Your trainer comes with a 24VDC 50 watt switching power supply. The trainer is designed for all switches, lights, relay/contactor, and even the heater to be powered by 24VDC making it much safer than 120VAC trainers.
- 3 Phase Motor/Fan - Your trainer comes with a 3 phase fan. It along with the item 7 AC drive allows for 3 phase principles to be taught when only 120VAC wall outlet power is available.
- Terminal blocks - To make your trainer more realistic, we have included terminal blocks for connecting to the 24VDC power supply and the heater. You may add more as you customize your trainer.
These trainers are built to order and typically take 2-4 days to ship.
Write a Review
×
Allen Bradley
Allen Bradley Micrologix 1400 PLC Trainer with Analog, AC Drive, 3 Phase Motor, and RsLogix 500 Software
Product Description
This is the Allen Bradley Micrologix 1400 Analog Trainer with everything you need to start your PLC programming career. Designed for both schools and individuals who wish to learn more than the basic trainers and instruction manuals can teach.
You can find all of your curriculum in the Lessons section including the "Allen Bradley RsLogix 500 PLC Trainer Lessons" and the "Designing And Building Electrical Control Panel Lessons".
The Micrologix 1400 PLC includes 10 discrete 24VDC inputs, 6 discrete 24VDC outputs, 2 analog inputs, and 2 analog outputs. RsLogix 500 Micro Starter is included with your trainer.
The trainer requires 120VAC and plugs into your typical wall outlet. The drive outputs 230 VAC to the three phase fan drive which is pre-wired on the trainer.
In addition to learning PLC programming and troubleshooting, these lessons will teach you how to wire and diagnose control systems. This curriculum will help you gain valuable insight into how industrial control panels are wired and operate. All circuits in these self paced lessons are 24VDC.
Your trainer includes:
- Push Button - Your trainer comes with four push buttons. A green, yellow, and blue momentary push button and a red maintained mushroom button (note image does not show mushroom button). Each button has two normally open (NO) contacts and two normally closed (NC) contacts. The normally open contacts are color coded green and the normally closed contacts are color coded red on the back of the trainer.
- Selector Switch 2 Position - Your trainer has two 2 position selector switches. There is a normally open contact on each selector switch that closes when you turn the switch to the right (clockwise).
- Selector Switch 3 Position - Your trainer has two 3 position selector switches. There is a normally open contact for both the left and right position of the selector switch.
- Lights - Your trainer has four lights colored green, yellow, red, and blue.
- Analog Potentiometer and Gauge - Your trainer has a 10K potentiometer and a 4-20mA analog gauge.
- Contactor Relay - Your trainer has one contactor/relay which is an open style so you can see how it works. It is a double pole double throw which means it has two sets of contacts with both normally open and normally closed positions.
- AC Drive - Your trainer has a AC inverter drive which takes 120VAC in and creates 240VAC 3 phase out so this trainer can be used to learn about 3 phase power yet plugs into a standard wall outlet.
- 24VDC Power Supply - Your trainer comes with a 24VDC 50 watt switching power supply. The trainer is designed for all switches, lights, relay/contactor, and even the heater to be powered by 24VDC making it much safer than 120VAC trainers.
- 3 Phase Motor/Fan - Your trainer comes with a 3 phase fan. It along with the item 7 AC drive allows for 3 phase principles to be taught when only 120VAC wall outlet power is available.
- Terminal blocks - To make your trainer more realistic, we have included terminal blocks for connecting to the 24VDC power supply and the heater. You may add more as you customize your trainer.
These trainers are built to order and typically take 2-4 days to ship.
Product Reviews
Write a Review
×